CBGCX - JEFFCO 1308 (RESIN COMPONENT)

  • MSDS: CBGCX
  • Manufacturer: JEFFCO PRODUCTS
  • Product Name: JEFFCO 1308 (RESIN COMPONENT)
  • National Stock Number: 8040-00N067570
Product Identification

Product ID:JEFFCO 1308 (RESIN COMPONENT)
MSDS Date:01/01/1993
FSC:8040
NIIN:00N067570
MSDS Number: CBGCX

Responsible Party
JEFFCO PRODUCTS
6252 KEAMY VILLA WAY
SAN DIEGO, CA 92123
US

Emergency Phone: 819-576-9900;800-424-9300(CHEMTREC)

Info Phone: 819-576-9900

Cage: JEFFC

Contractor
JEFFCO PRODUCTS
SAN DIEGO, CA 92123 US

Telephone: 619-576-9900

Cage: JEFFC

Ingredients

EPOXY RESIN

CAS: 25085-99-8

Fraction By Weight: 75-85%

OSHA PEL N/K

ACGIH TLV: N/K


ALKYL GLYCIDYL ETHER

CAS: 6809-97-2

Fraction By Weight: 15-25%

OSHA PEL N/K

ACGIH TLV: N/K


PROCESSES IS NOT BELIEVED TO BE CANCER HAZ TO

RTECS: 9999999ZZ


NEGATIVE. IT HAS BEEN SHOWN TO BE NEGATIVE IN SOME

RTECS: 9999999ZZ


SUPPORTIVE CARE. TREATMENT BASED ON

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT): > 4000 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: MINOR TRANSIENT IRRIT. NO
CORNEAL INJURY LIKELY. SKIN CONT: MAY CAUSE ALLERGIC SKIN RXN IN
SUSCEPTIBLE INDIVIDUALS. PRLNG EXPOS NOT LIKELY TO CAUSE
SIGNIFICANT SKIN IRRIT. RPTD EXPOS MAY C AUSE SKIN IRRIT. SKIN
ABSORPTION: SINGLE PRLNG EXPOS NOT LIKELY TO RSLT IN MATL BEING
ABSORBED THRU (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: SKIN IN HARMFUL AMTS. NO HAZ ANTIC
FROM INGEST INCIDENTAL TO INDUS EXPOS. INHAL: VAPS UNLIKELY DUE TO
PHYSICAL PROPERTIES. NOT PROBLEM UNLESS HEATED TO HIGH TEMP. EXCEPT
FOR SKIN SENSIT, RPT D EXPOS TO LOW MOLECULAR WT EPOXY RESINS OF
THIS TYPE HAS BEEN REPORTED TO PRODUCE SKIN CANCER IN HIGHLY (SUP
DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IRRIGATION OF EYE IMMED W/WATER FOR AT LEAST 15 MIN IS
GOOD SFTY PRACT. SKIN: CONT WILL PROBABLY CAUSE NO MORE THAN IRRIT.
WASH OFF IN FLOWING WATER/SHOWER. WASH CLTHG BEFORE REUSE. INGEST:
LOW IN TOX. NO ADVERSE EFTS ANTIC BY THIS RTE OF EXPOS INCIDENTAL
TO PROPER INDUS HNDLG. CALL MD IMMED . INHAL: REMOVE TO FRESH AIR.
CONSULT MED PERS. NOTE TO MD: NO SPECIFIC ANTIDOTE. (ING 5)

Fire Fighting

Flash Point Method:PMCC
Flash Point:486F,252C
Extinguishing Media:USE FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:SOAK UP IN ABOSRBENT MATERIAL AND COLLECT IN
SUITABLE CONTAINERS. RESIDUAL MAY BE REMOVED USING STEAM OR HOT
SOAPY WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PRACTICE GOOD CAUTION AND PERSONNEL
CLEANLINESS TO AVOID SKIN AND EYE CONTACT. AVOID BREATHING VAPORS
OF HEATED MATERIAL.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:GOOD ROOM VENTILATION USUALLY ADEQUATE FOR MOST OPERATIONS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:FOR BRIEF CONTACT, NO PRECAUTIONS OTHER THAN
CLEAN BODY-COVERING CLOTHING SHOULD BE NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD: WATER. THERMAL DECOMP PRODS OF EPOXY RESINS THEREFORE
SHOULD BE TREATED AS POTENTIALLY HAZ SUBSTANCES & APPROP PREC
SHOULD BE TAKEN. EFTS OF OVEREXP: SENSITIVE STRAIN OF MICE. HOWEVER
, HIGH LEVELS OF IMPURITIES COMPROMISE VALIDITY OF FINDINGS. EPOXY
RESIN THAT IS REPRESENTATIVE OF CURRENT MFG (ING 3)

Chemical Properties

Spec Gravity:1.11
Solubility in Water:NONE
Appearance and Odor:WATER-WHITE YELLOW LIQUID TO SEMI-SOLID, WITH FAINT
EPOXY ODOR

Stability

Stability Indicator/Materials to Avoid:YES
BASE.
Stability Condition to Avoid:EXCESS HEATING OVER LONG PERIODS OF TIME
DEGRADES THE RESIN.
Hazardous Decomposition Products:BY-PRODS EXPECTED IN INCOMPLETE
PYROLYSIS/COMBUST OF EPOXY RESINS ARE MAINLY PHENOLICS, CARBON
MONOXIDE & (SUP DAT)

Disposal

Waste Disposal Methods:BURN IN ADEQUATE INCINERATOR OR BURY IN AN
APPROVED LANDFILL. IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.